Skip to content
HOP THAI LOI

Metal materials

SUS 304 vs SUS 201 stainless steel for wire bending

How do SUS 304 and SUS 201 differ in composition, corrosion resistance, behaviour when bent and price? A guide to choosing the right stainless grade for bent wire parts by operating environment.

Published Updated

When ordering stainless steel bent wire parts — hooks, handles, wire frames, clips — the first question from engineering and purchasing is usually: SUS 304 or SUS 201? The two grades look almost identical to the naked eye, but differ clearly in corrosion resistance, machinability and price.

Chemical composition

Both are austenitic stainless steels, but 201 replaces part of the expensive nickel (Ni) with manganese (Mn) and nitrogen (N) to cut cost.

Element (reference)SUS 304SUS 201
Chromium (Cr)~18 – 20%~16 – 18%
Nickel (Ni)~8 – 10.5%~3.5 – 5.5%
Manganese (Mn)≤ 2%~5.5 – 7.5%
Nitrogen (N)≤ 0.1%≤ 0.25%

The higher chromium and nickel content lets 304 form a more stable passive film — the main reason 304 resists rust much better.

Corrosion resistance

  • SUS 304: copes well with humidity, water, light salt air and common cleaning chemicals; widely used in food, medical and outdoor applications.
  • SUS 201: suited to dry, indoor environments. With high humidity, salt water or chemicals, rust spots or yellow stains may appear over time.

Behaviour in wire bending

SUS 201 has higher tensile strength and work-hardening than 304. In practice in the workshop:

  1. Springback of 201 wire is larger, so more angle compensation is needed when programming the CNC machine.
  2. Bending force for the same wire diameter is higher, and bending tools wear faster.
  3. Small bend radii on 201 wire are more prone to micro-cracks if wire quality is inconsistent.

With 304, bend angles are more stable from coil to coil — especially important for 3D parts with many bends.

Vibratory polishing

Both grades polish to a bright finish. However, 304 surfaces usually keep their shine longer in use thanks to better stain resistance.

Quick identification in the warehouse

  • Magnet test: both are nearly non-magnetic when annealed, but may become slightly magnetic after cold bending — do not use a magnet as the only test.
  • Stainless test reagents: faster and more reliable.
  • Mill Test Certificate from the wire supplier is the most accurate evidence.

Which grade to choose?

Operating conditionsRecommendation
Outdoor, humid environments, cold storesSUS 304
Contact with food, water, cleaning chemicalsSUS 304
Indoor household items, dry environment, cost-sensitiveSUS 201
Complex 3D parts with tight tolerancesPrefer SUS 304

If you are unsure, send us your drawing and a description of the operating environment — Hop Thai Loi's engineers will recommend the grade that best balances cost and durability for each part number.